Test system>


  B-Tohin has established its professional center covered an area of 400 square meters for inspecting the blowers' comprehensive properties. And it also introduced the advanced CRAS signal collecting and monitoring system, that is used to collect and send signals such as air volume, blowing pressure, noise, vibration, rotary speed, temperature, electric current and electric voltage etc. to computer for realizing computers' on-line monitoring, analyzing, record storing and so on. The system ranks front in the same sector.


Testing Site
Sketch map of SLIP Test
    

  The "SLIP" means to test the blower rotary speed when pressure is 7 kpa and biggest inlet flowrate returned from outlet generated. By taking use of this method, we can test whether the blower clearance is up to standards and can calculate flowrate and cubage efficiency under every pressure.

SLIP & Cubage Curve
SLIP & Outlet Curve

Sketch map of test of blower package
Scope of Test
Data Unit Points tested in one time Tested range Precision of test Standard
Flowrate
m 3 /min
3
0-200
1.0%
JB/T8941.2-1999
Pressure
Kpa
6
0-200
1.0%
JB/T8941.2-1999
Noise
dBA
4
0-130
1.0%
GB/T2888-1991
Vibration
mm/s
3
0-99.9
3.0%
GB/T 11347
Speed
RPM
1
0-3600
0.2%
JB/T8941.2-1999
Temperature
o C
2
-20-250
± 1K
JB/T8941.2-1999
Current
A
6
800
0.5%
JB/T8941.2-1999
Voltage
V
6
600
0.5%
JB/T8941.2-1999
 
Testing and analyzing vibration
 



Testing and analyzing flowrate



Testing and analyzing noise


 