B-Tohin has established its professional center covered an area of 400 square meters for inspecting the blowers' comprehensive properties. And it also introduced the advanced CRAS signal collecting and monitoring system, that is used to collect and send signals such as air volume, blowing pressure, noise, vibration, rotary speed, temperature, electric current and electric voltage etc. to computer for realizing computers' on-line monitoring, analyzing, record storing and so on. The system ranks front in the same sector.
Testing Site |
Sketch map of SLIP Test
|
The "SLIP" means to test the blower rotary speed when pressure is 7 kpa and biggest inlet flowrate returned from outlet generated. By taking use of this method, we can test whether the blower clearance is up to standards and can calculate flowrate and cubage efficiency under every pressure.

|
SLIP & Cubage Curve
 |
SLIP & Outlet Curve
|
Sketch map of test of blower package
 |
Scope of Test
| Data
|
Unit
|
Points tested in one time |
Tested range |
Precision of test |
Standard |
| Flowrate |
m 3 /min |
3 |
0-200 |
1.0% |
JB/T8941.2-1999 |
| Pressure |
Kpa |
6 |
0-200 |
1.0% |
JB/T8941.2-1999 |
| Noise |
dBA |
4 |
0-130 |
1.0% |
GB/T2888-1991 |
| Vibration |
mm/s |
3 |
0-99.9 |
3.0% |
GB/T 11347 |
| Speed |
RPM |
1 |
0-3600 |
0.2% |
JB/T8941.2-1999 |
| Temperature |
o C |
2 |
-20-250 |
± 1K |
JB/T8941.2-1999 |
| Current |
A
|
6 |
800 |
0.5% |
JB/T8941.2-1999 |
| Voltage |
V |
6 |
600 |
0.5% |
JB/T8941.2-1999 |
|
| |
Testing and analyzing vibration
 |
| |

Testing and analyzing flowrate
|
|

Testing and analyzing noise
|